  1. Turn the ignition switch OFF and disconnect the battery negative (-) cable.
  2. Remove the floor under cover front RH.
  3. Disconnect the Exhaust Gas Temperature Sensor (EGTS) Front (A) and Rear (B).

  1. Remove the gasoline particulate filter (A).

Tightening torque : 39.2 - 58.8 N.m (4.0 - 6.0 kgf.m, 28.9 - 43.4 lb-ft)

  1. Install in the reverse order of removal.

WARNING

When installing, replace with new gaskets.

Center Muffler/ Rear Muffler

Center Muffler

  1. Remove the center muffler (A)

Tightening torque : 39.2 - 58.8 N.m (4.0 - 6.0 kgf.m, 28.9 - 43.4 lb-ft)

  1. Install in the reverse order of removal.

WARNING

When installing, replace with new gaskets.

Rear Muffler

Remove the rear muffler (A)

Tightening torque : 39.2 - 58.8 N.m (4.0 - 6.0 kgf.m, 28.9 - 43.4 lb-ft)

  1. Install in the reverse order of removal.

WARNING

When installing, replace with new gaskets.

    READ NEXT:

     Lubrication System

     Engine oil flow diagram

    Components Variable oil pump Variable oil pump sproket Oil Pressure & temperature sensor Oil filter Filter cap O-ring Filter cap Safety pin Oil cooler Engine oil flow diagram Replacement WARNING Prolonged and re

     Engine Oil

    Check the engine oil quality. Check the oil deterioration, entry of water, discoloring of thinning. If the quality is visibly poor, replace the oil. Check the engine oil level. After warning up the engine and then 10 minutes after the

    SEE MORE:

     Battery Module Inlet B Duct

    Remove the 48V battery assembly. (Refer to 48V Battery System - "Repair procedures") Remove the battery pack assembly inlet duct B (A) after loosening the mounting bolts. Install in the reverse order of removal. Sp

     Air Conditioning System - Instructions (R- 134a)

    When Handling Refrigerant R-134a liquid refrigerant is highly volatile. A drop on the skin of your hand could result in localized frostbite. When handling the refrigerant, be sure to wear gloves. It is standard practice to wear goggles or

    Information